We do ship to other countries. We have not decided on pricing yet. Please contact us under support@magglance.com for an individual offer.
Your document has been saved successfully.
Are you sure, you want to order the items in your shopping cart with the commitment to buy?
The PDF document you imported did not have the optimum format. To ensure optimal printing results, the PDF needs to be created in a format of 21.6 cm x 30.3 cm to avoid (small) white unprinted edges.
Do you want to print the magazine anyway?
Your order was successful. The invoice has been sent to you by email. You can also view your invoice in your order listing.
Your eMagazine is now also visible in your internal profile in the magazine overview.
The delivery time depends on the order volume and the order situation. In general, the below mentioned delivery times are adhered to, but please do understand that there may be discrepancies in rare cases. We recommend to consider sufficient extra time.
Shipping
Number of working days
normal (?)
about 5-10
quickly (?)
2-4
lightning (?)
1-3
Contact us for the expected delivery date. Large offers or shipping in countries outside of Germany can deviate from the upper delivery duration.
To print the magazine you must be logged in. If you are not a member yet, you can register for free.
Embed your created magazines on your website. Copy the script below and paste it on to your HTML code:
34
UNIDAD DE VENTILACIÓN GERMICIDA
R
La característica principal de los sistemas de esterilización
de aire UVC es su capacidad para limpiar el aire destruyendo
los microorganismos presentes (virus, bacterias y hongos).
Los filtros HEPA capturan los microorganismos y los retienen
dentro de sus fibras, lo que les permite mantenerse viables
en el filtro fibroso que puede ser una fuente de infección. En
cambio, el sistema de esterilización por aire UVC de ALZIONE
destruye, en breve espacio de tiempo, los microorganismos
presentes alterando su ADN/ARN y anulando su capacidad de
reproducirse.
El sistema de desinfección de ALZIONE está considerado,
gracias a su diseño, como el más eficaz de los sistemas
contra el SARS CoV-2.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0 minutos
6 minutos
12 minutos
›
99.999%
(log 5)
Antes de la desinfección
Después de la desinfección
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0 minutos
6 minutos
12 minutos
›
99.9999%
(log 6)
Antes de la desinfección
Después de la desinfección
Dosis de radiación UVC necesaria en diferentes microorganimos (J/m
2
)
% de reducción
99% 99,9% 99,99% Estudio
(2 log) (3 log) (4 log) realizado por
Bacterias
Pseudomonas aeruginosa (NCTC 10662) 26 38 50 Blatchley et al. 2016
Burkholderia pseudomallei (ATCC11688) 35 55 74 Rose & O´Conell 2009
Escherichia coli (ATCC 13033) 30 47 65 Sholtes et al. 2016
Staphylococcus aureus (BAA-1556) 72 88 100 McKinney & P. 2012
Legionella pneumophila (ATCC 43660) 50 72 93 Wilson et al. 1992
Mycobacterium tuberculosis 30 85 145 Boshof et al. 2003
Salmonella typhimurium 53 67 77 Hu et al. 2012
Stenotrophomonas maltophilia
200 Univ. Leeds, UK 2000
Hongos
Encephalitozoon intestinalis 56 84
John et al. 2003
Virus
Hepatitus A (HM175)
174 Battigelli et al. 2002
SARS-CoV2
21 33 45 Univ. Boston 2020
Ebola virus
30 63 Sagripanti & L. 2010
PRUEBAS CIENTIFICAS
Resultados logrados en laboratorio homologado y acreditado por la Direccion General
de Salud Pública.
Bacteria utilizada:
Stenotrophomonas maltophilia: bacilo gramnegativo, aerobio, móvil, ampliamen-
te difundido en el medio ambiente y patógeno humano oportunista multirresistente,
especialmente del tracto respiratorio.
Equipo: Coriolis
Reducción después
de 6 minutos: 99,999%
(en una sola pasada
del aire por la máquina)
Dosis: ›200 J/m
2
Dosis de radiación UVC necesaria en diferentes microorganimos (J/m
2
)
% de reducción
99% 99,9% 99,99% Estudio
(2 log) (3 log) (4 log) realizado por
Bacterias
Pseudomonas aeruginosa (NCTC 10662) 26 38 50 Blatchley et al. 2016
Burkholderia pseudomallei (ATCC11688) 35 55 74 Rose & O´Conell 2009
Escherichia coli (ATCC 13033) 30 47 65 Sholtes et al. 2016
Staphylococcus aureus (BAA-1556) 72 88 100 McKinney & P. 2012
Legionella pneumophila (ATCC 43660) 50 72 93 Wilson et al. 1992
Mycobacterium tuberculosis 30 85 145 Boshof et al. 2003
Salmonella typhimurium 53 67 77 Hu et al. 2012
Stenotrophomonas maltophilia
200 Univ. Leeds, UK 2000
Hongos
Encephalitozoon intestinalis 56 84
John et al. 2003
Virus
Hepatitus A (HM175)
174 Battigelli et al. 2002
SARS-CoV2
21 33 45 Univ. Boston 2020
Ebola virus
30 63 Sagripanti & L. 2010
0
50
100
150
200
250
SSeudomonas aeruginosa (NCTC 10662)
Burkholderia pseudomallei (ATCC11688)
Escherichia coli (ATCC 13033)
Staphylococcus aureus
Legionella pneumophila
Mycobacterium tuberculosis
Salmonella typhimurium
Stenotrophomonas maltophilia
Encephalitozoon intestinalis
Hepatitus A (HM175)
SARS-CoV2
Ebola virus
Dosis UTGE (ALZIONE)
Dosis de radiación UVC necesaria en diferentes microorganimos (J/m
2
)
para una desinfección del 99,99%
PRUEBAS DE SEGURIDAD
Controles efectuados por SGS.
Pruebas realizadas tras una hora de funcionamiento de la máquina en un espacio
reducido.
Medición de Compuestos volátiles orgánicos (VOC´s): no se encontró ninguna
alteración en los compuestos estudiados tras el funcionamiento de la máquina de
desinfección (desinfección realizada por medio físico, no químico).
Entre los componentes se monitorizaron: etanol, benceno, fenol, tolueno, etil bence-
no, ciclohexanona, acetato de butilo, de entre 50 compuestos medidos. Ninguno de
estos compuestos indicados sufrió modificación, ni se generaron nuevos compuestos
volátiles orgánicos. Para esta prueba se tuvo en cuenta la norma ASHRAE 62-1999 y
la nota técnica INSHT 607.
OZONO (O
3
): Para la realización de esta prueba se tuvieron en cuenta los
límites INSHT (0,01 ppm) de ozono para exposiciones prolongadas.
Nuestro equipo incorpora lámparas germicidas de la marca Philips, las cuales
disponen de sus correspondientes certificaciones, sin embargo dentro de
nuestro sistema de control de calidad, encargamos a la empresa acreditada,
SGS, la realización de los ensayos que confirmaron la ausencia de producción
de ozono en el normal funcionamiento de nuestro equipo..
Fuga radiación UVC: La medición se realizó por SGS mediante un barrido alrededor
de la máquina sin que se detectara ningún tipo de fuga.
6 renovaciones
por hora.
- APLICACIONES -
Número de renovaciones de aire por hora recomendadas
6 renovaciones por hora.
4 renovaciones
por hora.
(Renovaciones a realizar con la máquina UTGE. Se han de tener en cuenta de forma independiente
las renovaciones de aire exterior que marca el RITE y las medidas de seguridad dictadas por Sanidad)
PATENTADO
HOSPITALES
CLÍNICAS
FARMACIAS
- APLICACIONES -
Número de renovaciones de aire por hora recomendadas
3 renovaciones
por hora.
- APLICACIONES -
Número de renovaciones de aire por hora recomendadas
4 renovaciones
por hora.
3 renovaciones por hora.
(Renovaciones a realizar con la máquina UTGE. Se han de tener en cuenta de forma independiente
las renovaciones de aire exterior que marca el RITE y las medidas de seguridad dictadas por Sanidad)
(Renovaciones a realizar con la máquina UTG. Se han de tener en cuenta de forma independiente
las renovaciones de aire exterior que marca el RITE y las medidas de seguridad dictadas por Sanidad)
PATENTADO
AULAS
TIENDAS,
RESTAURANTES..
SUCURSAL BANCARIA
- Dosis -
CAUDAL DE AIRE (Modo día / noche)
MODELO
NIVEL SONORO (Modo día / noche)
dBA
V/F/Hz
ALIMENTACIÓN
CONTROL SIEMENS FUNCIONES
ALTO
ANCHO
mmmm
Kg
FONDO
PESO
CONFIGURACIONES POSIBLES
MOTOR VENTILADOR
1 - HORIZONTAL VISTO - Retorno por detrás, impulsión frontal.
2 - HORIZONTAL VISTO - Retorno por debajo, impulsión por delante.
3 - HORIZONTAL OCULTO - Conducto
Estándar - VERTICAL VISTO - Retorno por arriba, impulsión por abajo.
TIPO
VELOCIDADES
UTG-70P63
DIMENSIONES
UNIDAD DE VENTILACIÓN GERMICIDA
CONSUMO ELÉCTRICO
REACTOR UVC
J/m
2
400 / 200
›
160
376
54 / 32
AC
1 a 6 (2 conectadas)
G4
1360
750365
41
UTGE-120P125
UTGE-220P185
m
3
/h
800 / 400
220-240 / 1 / 50
›
200
800
58 / 45
DC
0 - 10
EU5
F7 - F9 - CARBÓN ACTIVO - LAVABLE
Wifi - Display - Reloj - CO
2
- Control Radiación UVC - Consumo Motor
Fallo motor - Filtro sucio - Control horas funcionamiento lámparas
18101010
365116
W
mm
1300 / 800
›
200
1075
61 / 48
DC
0 - 10
EU5
18101475
365139
FILTRO DE AIRE
OPCIONAL
UNIDAD DE VENTILACIÓN GERMICIDA
R
UNIDAD DE VENTILACIÓN GERMICIDA
R
ALZIONE SISTEMAS, S.L.
Parque Científico de Madrid
Campus de Cantoblanco
C/ Faraday, 7
28049 Madrid (España)
www.alzione.eu
info@alzione.eu +(34) 91 737 85 00
Prestaciones (disponibles):
- Control vía Wifi.
- Control CO
2
.
- Programación horaria.
- Contador horario de funcionamiento de lámparas.
- Medición de radiación UV emitida.
- Control velocidad de aire.
- Monitorización consumo motor.
- Detección de filtro sucio.
- Salida para arranque ventilador externo en función de la concentración de CO
2
.
- Desconexíon en caso de apertura.
- Rearme automático.
Mantenimiento:- Lámparas: 8.000h
- Filtro: cuando lo indique el control o una vez al año.
El fabricante se reserva el derecho de hacer cualquier modificación o mejora sin previo aviso.